Experience Reichert®️ at AAO in Chicago at Booth 3857 for the latest technologies in glaucoma care and refraction!

Tono-Pen AVIA® with Quick-Tap® Measurement Mode

Measure Quickly and Confidently with Tono-Pen AVIA.

Tono-Pen AVIA® with Quick-Tap® Measurement Mode builds on all the features that made the classic Tono-Pen® XL the most widely used handheld tonometer. Tono-Pen AVIA requires no calibration and is always ready-to-use, has an award-winning ergonomic design, longer battery life, and an enhanced IOP averaging technique with two measurement modes. This makes it the most advanced Tono-Pen yet! Demo Tono-Pen AVIA at American Academy of Ophthalmology in Chicago at Booth 3857.

Promotion Available - Purchase 2 (two) or more Tono-Pen AVIA® Handheld Tonometers during the promotional period and receive an instant $500 manufacturer's rebate for each pen purchased. Promotion can be combined with the $500 trade-in offer, for a total savings of up to $1,000 each! Offer available in the USA and Canada only, from August 22, 2022 through October 31, 2022 (or while supplies last). Request Quote.

BUY NOW - INSTANT REBATE »

Ocular Response Analyzer® G3 

Significance of Corneal Hysteresis in predicting glaucoma development, in 25 seconds with Felipe Medeiros, MD.

Felipe Medeiros, MD briefly describes the relevance of his new publication: A Prospective Longitudinal Study to Investigate Corneal Hysteresis as a Risk Factor for Predicting Development of Glaucoma. Corneal Hysteresis was found to be independently more predictive of conversion to glaucoma than other risk factors, including IOP and CCT.

Ocular Response Analyzer® (ORA) G3 is the only device that measures Corneal Hysteresis (CH) and Corneal Compensated IOP (IOPcc). Corneal Hysteresis has consistently shown to be a more powerful predictor of, and strongly associated with, glaucoma progression, more so than key risk factors such as IOP and CCT. IOPcc is a pressure measurement that is less affected by corneal properties and more associated with glaucoma risk than Goldmann and other tonometers. Ocular Response Analyzer is engineered, designed, and assembled in USA. 

Glaucoma Vitals You May Be Missing - Corneal Hysteresis & IOPcc - Hosted by Ike Ahmed, MD 3/25/2021

FModerator Ike Ahmed, MD, was joined by distinguished glaucoma experts including Gus Gazzard, MD, and Cynthia Roberts, PhD, to discuss the evidence and case studies supporting Corneal Hysteresis (CH) and Corneal Compensated IOP (IOPcc) as new "glaucoma vitals" and how these parameters have improved their glaucoma decision making and treatment stratification. Gus Gazzard recently authored an editorial suggesting IOPcc should be the new gold standard for IOP measurement. Corneal Hysteresis and IOPcc measurements are provided by the Ocular Response Analyzer® G3 from Reichert®.

Moderator: Ike Ahmed, MD
 
Panelists: Gus Gazzard, MD, Marc Toeteberg-Harms, MD (Unable to attend due to patient emergency), Cynthia Roberts, PhD. 

Glaucoma Risk - Doctor to Doctor Talks - AAO - Chicago, IL

Saturday, 10/01/22: 10:00 AM -12:00 PM 
Gus Gazzard, MD
Consultant Ophthalmic Surgeon
Moorfields Eye Hospital, London

Saturday, 10/01/22: 1:00 PM -3:00 PM 
Anthony Khawaja, MD
Consultant Ophthalmic Surgeon
Moorfields Eye Hospital, London

Sunday, 10/02/22: 10:00 AM -12:00 PM 
Nathan Radcliffe, MD
Cataract & Glaucoma Specialist
New York Eye Surgery Center

Sunday, 10/02/22: 1:00 PM -3:00 PM 
Paul Singh, MD
President
The Eye Centers of Racine and Kenosha


Promotion Available - Purchase an Ocular Response Analyzer® G3 during the promotional period and receive a $1,000 manufacturer's rebate. Offer available in the USA and Canada only, from August 22, 2022 through October 31, 2022. 

LEARN MORE & SEE REBATE OFFER »



Tono-Vera® Tonometer  
 

Introducing the all-new Reichert® Tono-Vera Tonometer featuring the advanced, patent-pending ActiView™ Positioning System, your guided view to precise IOP measurements. Using gentle rebound tonometry technology, Tono-Vera automatically measures when aligned, providing more objective and repeatable results. For over 150 years, Reichert continues to advance tonometry and refraction diagnostics through American innovation.

 

Phoroptor® VRx Digital Refraction System

 

 

A Premium Refraction Experience – Phoroptor VRx.

When building Eyesite, Benjamin Peters, OD & Justin Verrone, OD understood the importance design plays in their patients' experience. 

Refract safely from across the room or across the internet. Exceed your patients' expectations with a premium refraction experience. Featuring the thinnest, most compact design, incredibly fast lens exchange, and ultra-quiet operation, Reichert Phoroptor VRx Digital Refraction System sets a new standard in refraction. Phoroptor VRx effortlessly integrates into your practice and is telehealth capable. Designed & assembled in the USA. Phoroptor is a registered trademark of Reichert, Inc.


ClearChart® Digital Acuity Systems



The family of ClearChart® Digital Acuity Systems from Reichert are all-in-one, elegant, and simple-to-use. They are uniquely designed to meet all of your acuity testing needs with a wide selection of optotypes and other special test charts. The ClearChart 4 Digital Acuity System, ClearChart 4X Enhanced Digital Acuity System, and ClearChart 4P Polarized Digital Acuity System all feature a 24-inch, high-resolution, LED-backlit display, and are lightweight, cool-running, and long-lasting. ClearChart seamlessly connects to Reichert digital Phoroptors for the best possible refraction experience for both you and your patient. 

LensChek® Digital Lensometer®



The LensChek® Plus Digital Lensometer®, part of the VisionChek™ Digital Exam Suite, combines technology with simplicity at the core of your exam. The compact, modern design and intuitive user interface of the LensChek Plus Digital Lensometer offers the easiest lensmeter user experience available. For example, when the target is aligned with the correct optical center, readings can be automatically “locked-in” ensuring fast, repeatable, and reliable lens measurement. The LensChek® Pro Digital Lensometer® with PD + UV offers the additional features of UV transmittance and PD measurement.

LEARN MORE »


OptoChek® Plus Auto Refractor + Keratometer

The OptoChek® Plus Auto Refractor + Keratometer, part of the VisionChek™ Digital Exam Suite, combines technology with simplicity at the core of your exam. The new, compact, modern and intuitive design of the OptoChek Plus offers the easiest user experience available for measuring objective spherical and cylindrical refractive errors as well as keratometry.

LEARN MORE »

Phoroptor® By Reichert® - Celebrating 100 Years of Making Vision Clearer 



Reichert's commitment is to manufacture high-quality refraction devices that give eye care professionals the ability to provide clearer vision to their patients. Innovation is at the core of Reichert and Phoroptor is no exception. It’s hard to imagine the eye care industry without it!

What's next for Phoroptor in the 100 years to come? Want to be the first to find out how we're going to celebrate Phoroptor this year? Fill out the form and we'll keep you in the loop!